44 Output Coordinated Intelligent Traffic Signal Controller
Model:XHJ-AW-GA-JKC100
Housing Material:Aluminium alloy
Working Voltage:176-264VAC 50+2HZ
Operating Temperature:-40℃~+70℃
Working Humidity:≤95%
Certificates:ISO9001,GB25280-2016
Product Description:
1.In accordance with the requirements of GB 25280-2016 "Road Traffic Signal Controller.
2.Built-in central control system to ensure work stability.
3.Easy for maintenance and function extension by modular design.
4.Parameter setting: modify the signal parameters through the LCD screen, or modify it through the background host computer.
5.Remote control: all settings and special control of the signal can be realized in the background.
6.Communication interface: one Ethernet interface (RJ45), four RS485 interface,six RS232 interface.
7.Output drive capability: 44 outputs, each with a load capacity of 800W.
8.Independent LED analog intersection shows the working status of the intersection signal light.
9.Yellow flashing frequency: The frequency of the yellow flashing signal is 60 times/min, and the bright &dark time ratio is 1:1.
10.Failure Monitoring function:When there is a green light conflict,All red lights or green lights of a signal group are extinguished,The signal controller can automatically cut off the signal output channel and immediately switch to the yellow flash control mode.
11.GPS automatic timing function supported.
12.Insulation resistance:The insulation resistance of Signal power electrode or other conductive parts between Accessible and outer casing is more than 500MΩ.
13.The signal controller is with function including multi-time timing control, no cable coordination control, background host computer control, special holiday control, guard task control function.
Technical Parameter:
Item | Technical Parameter |
Executive Standard | GB25280-2016 |
Working Voltage | 176-264VAC 50+2HZ |
Working Frequency | 50+2HZ |
No-load power | ≤30W |
Each Output Drive Capability | 3A |
Communication interface | RJ45,RS232 |
Each load output capacity | 800W |
Working menus | 23 |
Can be setup menus number | 30 |
The largest number of each menus | 32 |
The largest number of timers in each day | 24 |
Running time in each step | 1~255S |
Full red transition time | 0~10S |
Yellow light transition time | 3~6S |
Green flashing time | 0~3S |
Operating Temperature | -40℃~+70℃ |
Working Humidity | <95% |
Insulation resistance | >500MΩ |
Setting Plan Saving Time(The electricity was turned off) | 10 years |
Time Error | Year error<2.5 minutes(in the condition of 25±1℃) |