44 Outputs Networking Intelligent Traffic Signal Controller
Model:XHJ-CW-GA-JKC200 Standard Edition
Housing Material:Cold-rolled Steel
Working Voltage:176-264VAC 50+2HZ
Operating Temperature:-40℃~+70℃
Working Humidity:≤95%
Certificates:ISO9001,GB25280-2016
Product Functions:
1.Multi-time period control:User can set multi-time periods of different schemes on weekdays, weekends and special holidays.
2.Green wave band control:Coordinate the operation of signals at various intersections by GPS so as to achieve the pre-formulated control scheme.
3.Automatic adaptive control: The signal control parameters are automatically adjusted in real time according to the traffic flow information.
4.Networked control: User can send instructions and data to the signal machine remotely through the network to understand its operation state.
5.Pedestrian crossing: Provides the pedestrian key input channel to optimize the passage.
6.Police task control: Police can separately clear the motorway in one direction under special circumstances through manual control panel or background software.
7.Manual stepping control: Can manually intervene the traffic signal status under special circumstances.
8.Fault automatically detection: If there is a fault, the signal light will automatically turn yellow.
9.Traffic flow detection: traffic flow data can be continuously recorded.
Optional Special Functions:
1.can control the status of signal lamp through the remote control.
2.Current, Voltage, Temperature and Humidity can be detected.
3.User can directly set the countdown timer display color and time.
4.It will light up and alarm automatically when Opening or closing the front door, back door and side door of the cabinet.
Technical Parameter:
Item | Technical Parameter |
Executive Standard | GB25280-2016 |
Working Voltage | 176-264VAC 50+2HZ |
Working Frequency | 50+2HZ |
No-load power | ≤30W |
Each Output Drive Capability | 3A |
Communication interface | RJ45,RS232,RS485 |
Each load output capacity | 800W |
Working menus | 23 |
Can be setup menus number | 30 |
The largest number of each menus | 32 |
The largest number of timers in each day | 24 |
Running time in each step | 1~255S |
Full red transition time | 0~10S |
Yellow light transition time | 3~6S |
Green flashing time | 0~3S |
Operating Temperature | -40℃~+70℃ |
Working Humidity | <95% |
Insulation resistance | >500MΩ |
Setting Plan Saving Time(The electricity was turned off) | 10 years |
Time Error | Year error<2.5 minutes(in the condition of 25±1℃) |